Nigeria’s power grid has maintained uninterrupted stability for over 400 consecutive days.
This is according to the Transition Company of Nigeria (TCN).
Spokesperson of the company, Ndidi Mbah, in a statement, said the power grid operated without any major disruptions or systems collapse within the period.
She attributed the feat to a combination of strategic measures and investments in the power system by the Management of the TCN.
According to her, the milestone signifies a remarkable advancement in the nation’s efforts at strengthening its power infrastructure and ensuring a reliable and dependable electricity supply to distribution load centres for onward distribution to customers nationwide.
Mbah said some of the key elements that contributed to the feat include the “configuration and enforcement of free governor control, effective under-frequency relay scheme, among others”.
She said TCN constituted a three-person committee to go round the country for the “configuration and activation of primary reserve in coordination with power stations and in line with the provisions in the Grid code”.
“This committee devised a robust monitoring and enforcement mechanism for generating station compliance after activating the unit governor control,” the spokesperson said.
“This innovative approach, known as free governor mode of operation (FGMO), automatically adjusts generation in response to frequency changes, ensuring stability, reliability, and reduced transmission losses.
“Under frequency relay scheme, counters the challenges posed by occasional generation shortfalls and resulting frequency declines, TCN implemented a strategic deployment of under frequency relay scheme.”
The scheme, according to Mbah, operates in critical stages to prevent frequency-related disruptions by initiating circuit breaker trips or alerting network operators, thereby averting system collapses.
“TCN in-house engineers deployed the loT/VPN for Enhanced Grid Visibility by creating an interim solution utilizing lot sensors and devices. This real-time monitoring capability aids proactive issue identification, preventing potential disruptions,” she said.
“Efforts are ongoing to expand this visibility by incorporating additional transmission stations through lot integration TCN successfully carried out several Infrastructure Upgrades / N-1 contingency transforming the grid from a radial network to a loop system through massive investment in construction and dualisation of critical circuits, comprehensive modernization of transmission infrastructure, including commissioning new transmission stations and installing power transformers, has reinforced grid resilience and operational flexibility.
“The company equally focussed on putting in place an enhanced maintenance regime with regular inspections, prompt repairs, and proactive preventive maintenance strategies to ensure the integrity of power plants, transmission lines, and substations. This approach sustains infrastructure health, operational reliability, and efficient power flow.
“Regular maintenance has equally ensured less equipment downtime due partly to regular mechanised line trace which has prevented vegetation from fouling transmission lines. This has helped reduce downtime especially in forest areas where TCN transmission lines transverses.”